<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-26 16-03-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 4/5, 27 dBuV R-CB
Pilot RDS Phase Difference
6.6 kHz 2.6 kHz 82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
15 kHz 39 kHz 9586 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,5 dBr -1,04 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-CB " 250D 9 (Varied) 1 1 0 0 16:03, 26.04.2024
RT
" e pisn te si zazpivate "
AF EON
88.2, 103.9, 106.4 MHz -
FM Scope Max at: 39 kHz MIN: 15 kHz % above 77 kHz: 0,0000 Acquired: 2024/04/26 16:03:22 Total samples: 9586 Equivalent time: 0:07:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,5 dBr MIN: -1,5 dBr AVE: -1,04 dBr % above 0,2 dBr: 0,0 Last value: -1,3 dBr (2024/04/26 16:03:22) 15:50 15:52 15:54 15:56 15:58 16:00 16:02 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality